產(chǎn)品列表PRODUCTS LIST
本頁面標準信息均來源于網(wǎng)絡(luò)收集,或由參與標準制定的供應(yīng)商提供,只作為參考使用,為確保測試結(jié)果的準確性、節(jié)省您的時間,如需FLTM BO 116-01_2007標準詳細信息或FLTM BO 116-01_2007具體測試方法,請與我們技術(shù)人員聯(lián)系或給我們留言,我們將為您提供相關(guān)的技術(shù)支持。
FLTM-BO-116-01 汽車內(nèi)飾材料暴曬試驗標準:水冷式氙弧燈氣候試驗箱方法
EXPOSRE OF INTERIOR TRIM MATERIALS IN A CONTROLLED IRRADIANCE
WATER COOLED XENON-ARC APPARATS
This procedure is used to determine the effects of simulated weather on interior trim materials using a controlled irradiance water cooled xenon-arc Weather-Ometer® with an auxiliary lantern and filters.
Operating Filter
335 nm long pass filters (SF-5 filters) or equivalent provided the transmission spectrum is within 95% of the SF-5 filter transmission at all wavelengths. The filters are reversible unless otherwise marked by a coating or etching.
Dimensions for the Ci 5000 series Weather-Ometer®:
339 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm
Dimensions for the Ci 3, Ci 6 & Ci 4000 Weather-Ometer®:
220 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm
Lamp Sensor Irradiance Filter
420 nm Irradiance Filter
Available from:
Atlas Material Testing Technology LLC
4114 Ravenswood Ave.
Chicago, IL 60613 SA
Calibration Lamp
The calibration lamp must be calibrated to 420 nm with the lantern assembly removed.
Available from:
Atlas Material Testing Technology LLC
4114 Ravenswood Ave.
Chicago, IL 60613 SA
Sample Conditioning
All test values indicated herein are based on material conditioned in a controlled atmosphere of 21 +/-2 °C and 50 +/- 5% relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified.
Test Conditions
Testing conditions such as black panel temperature, dry bulb temperature, humidity, light cycle times and dark cycle times are equivalent to those outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Table 1,Section 6.1.5.
Place the 335 nm long pass filters (SF-5 filters) or equivalent into the auxiliary lantern. Orient thelantern around the xenon-arc lamp assembly which is equipped with the Quartz/Type "S" Borosilicate filtered xenon-arc lamp source as outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Apparatus Set-p, Section 6.
Exposures are monitored based on measured light at 1.06 W/m2 -/nm@420 nm SAE J2412 –Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance XenonArc Apparatus, Table 1.
Equipment Calibration
As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A, Section A.3 and Appendix B.
Equipment Maintenance
As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A.
Note: SF-5 auxiliary filters should be cleaned at every lamp calibration period or more frequent if necessary.
SF-5 filters and the 420 nm interference filter should be changed per the manufacturer's recommendations/or within 13,000 hours of use.
Sample Exposure
As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Test Procedure, Section 7.
Sample Evaluation and Exposure Report
As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Evaluating and Reporting, Section 8 and Exposure Report, Section 9.
AATCC Gray Scale, 10 Step, According to AATCC Evaluation Procedure 1/ISO 105-A02 for Evaluation of Color Change.
pon request measure the gloss with a 60° glossmeter (or as specified in the applicable Engineering Standard) according to FLTM BI 110-01. Record the unexposed and exposed gloss.
Chemicals, materials, parts and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.